Sensors type platform SSP 10-20-40-80-120 kg
The SSP strain gauge is designed to work in systems with a single weighing point. Compensation in a wide temperature range, high sensitivity – important advantages of SSP sensors. As a rule, they are used in platform scales of low power, which are equipped with a platform of no more than 50 × 50 cm, as well as in systems with high power.
| Rated load (Emax) |
kg |
10, 20, 40, 80, 120 |
| Accuracy class (OIML R 60) |
|
|
| Discreteness by class ( n LC ) |
|
|
| Minimum weighing interval (V min ) |
|
|
| A common mistake |
% |
|
| Error of return to zero (DR) |
% Emax |
0.008 |
| Minimum load |
% Emax |
0 |
| Maximum overload |
% Emax |
100 |
| Permissible horizontal overload |
% Emax |
100 |
| Destructive overload |
% Emax |
200 |
| Deformation (at Emax) |
mm |
≤0.6 |
| Maximum excitation voltage (Umax) |
IN |
15 |
| RCP (Cn) |
mV / V |
2 ± 0.1% |
| Zero balance |
% Cn |
≤ ± 1.0 |
| Input impedance |
Ω |
385 ± 20 |
| Output resistance |
Ω |
350 ± 3 |
| Insulation resistance |
MOm |
≥500 |
| Compensated operating range |
° С |
-10 … + 40 |
| Operating temperature range |
° С |
-40 … + 80 |
| Sensor material |
|
Stainless Steel |
| Protection class (according to EN60529 classification) |
|
IP66 |
| Cable length |
m |
5 |
| Cable diameter |
mm |
5 |
| Mass |
kg |
0.8 |
| Package weight and dimensions |
cm / kg |
10x27x6 / 0.9 |