Strain gauges HC 200 t
The column-type model of the HC strain gauge works in compression.
The main field of application of NS strain gauges is test machines that work with high loads and do not require high measurement accuracy.
The degree of protection of the steel body of the sensor is IP65. The casing is made of anti-corrosion material.
The sensor is protected from overloads and external influences.
| Rated load (Emax) | kg | 200,000 |
| Accuracy class (OIML R 60) | ||
| Discreteness by class ( n LC ) | ||
| Minimum weighing interval (V min ) | ||
| A common mistake | % Emax | ≤±0.05 |
| Error of return to zero (DR) | % Emax | |
| Minimum load | % Emax | 0 |
| Maximum overload | % Emax | 200 |
| Permissible horizontal overload | % Emax | |
| Destructive overload | % Emax | 400 |
| Deformation (at Emax) | mm | |
| Maximum excitation voltage (Umax) | IN | 15 |
| RCP (Cn) | mV/V | 2 |
| Zero balance | % Cn | ≤±1.0 |
| Input impedance | Ω | 385±20 |
| Output resistance | Ω | 350±3 |
| Insulation resistance | MΩ | ≥500 |
| Compensated operating range | °C | -10…+40 |
| Operating temperature range | °C | -40…+80 |
| Sensor material | Steel | |
| Protection class (according to EN60529 classification) | IP65 | |
| Cable length | m | 13 |
| Cable diameter | mm | 8 |
| Mass | kg | 11.2 |
| Package weight and dimensions | cm / kg | 25x25x17.5 / 12.2 |









Reviews