Normalizing amplifier – LCA X amplifier
Amplifiers and weighing terminals of the LCA-X model are mainly used in weighing systems that have the possibility of remote control and reading of information from a remote PC, since the device does not have a display.
Control using the Modbus protocol is the main advantage of the amplifier. The use of this protocol allows you to read all weighing data and manage all software parameters. It is possible to control several terminals at once if they are connected to one communication line.
Programs for the Windows ™ OS were developed specifically for the connection between the computer and the terminal. One of them, DLMS_VP, is designed to connect a PC with only one device and control it, the other – DLMS_NW, can connect a PC with several devices at the same time, as well as with devices connected to another PC located in the local network.
The body is completely wet and dustproof, resistant to corrosion, the material is cast aluminum.
Features of the LCA X amplifier:
- Dust- and moisture-proof housing made of cast aluminum
- Tare input in the entire weighing range
- Determination of the output range according to the connected sensors
- Digital linearization
- Digital temperature compensation
- Remote control of all parameters (Modbus)
- DLMS_VP program for communication with one device
- Serial port RS232 / RS485>
| Sensitivity |
|
| Number of verification intervals (Class of accuracy) |
7000d (III) |
| Input sensitivity |
0.5μV / discharge |
| Error |
3.6 pages / min / ° C |
| Temperature stability of readings |
24 bit Sigma-Delta |
| ACT |
0.003% |
| Digital filter |
Numerical averaging variable |
| Frequency |
50 Hz |
| Sensors |
|
| Maximum number of sensors |
8 pcs (350Ω) |
| Working coefficient of strain gauges |
± 160 mV / V |
| Supply voltage |
10V direct current |
| Environment |
|
| Operating temperature range (approved by MOZM) |
-10 ° C + 40 ° C |
| Storage temperature range |
-20 ° C + 70 ° C |
| Supply voltages and amperage |
10-35 V DC – 5 W |
| Button control and display |
|
| Button control |
– |
| Weight display |
– |
| Functional display |
– |
| Program display |
– |
| Corps |
|
| Material and protection class |
Aluminum, IP66 |
| Mass |
1 kg |
| Dimensions and weight of the package |
1.1 kg, 15x24x6 cm |
| Communication |
|
| Serial port |
|
| Parallel printer port |
|
| Binary output (BCD) |
|
| Output to external display |
|
| Output to external display |
| – |
2 digital outputs (relay 2A) |
|
| Analog output |
|
* Digital port and BCD output are not used at the same time.