Strain gauges HSC 40-60-100 t
The HSC sensor model operates on the principle of compression, measuring force and mass with high accuracy that is not lost even under heavy overloads. Vertical or horizontal loads, as well as difficult working conditions, do not affect the functionality of the HSC load cell. The steel case, covered with anti-corrosion paint, has a degree of protection IP68. Strain gauges are protected by a stainless steel plate.
The main field of application is automatic weighing systems, wagon or car scales, tank weighing systems.
| Model | Nominal load | Minimum interval | Maximum overload |
| HSC 40 | 40,000 kg | 8000 g | 60,000 kg |
| HSC 60 | 60,000 kg | 12000 g | 90,000 kg |
| HSC 100 | 100,000 kg | 20,000 g | 150,000 kg |
| HSC 200 | 200,000 kg | 120,000 g | 300,000 kg |
| HSC 20 does not meet OIML R60 standards | |||
| Rated load (Emax) | kg | 40000, 60000, 100000, 200000 |
| Accuracy class (OIML R 60) | C1 c3 | |
| Discreteness by class ( n LC ) | 1000 3000 | |
| Minimum weighing interval (V min ) | Emax / 3500 Emax / 6750 | |
| A common mistake | % Emax | ≤ ± 0.05 ≤ ± 0.02 |
| Error of return to zero (DR) | % Emax | 0.0039 |
| Minimum load | % Emax | 0 |
| Maximum overload | % Emax | 150 |
| Permissible horizontal overload | % Emax | 100 |
| Destructive overload | % Emax | 300 |
| Deformation (at Emax) | mm | ≤0.3 |
| Maximum excitation voltage (Umax) | IN | 15 |
| RCP (Cn) | mV / V | 2 ± 0.1% |
| Zero balance | % Cn | ≤ ± 1.0 |
| Input impedance | Ω | 385 ± 20 |
| Output resistance | Ω | 350 ± 3 |
| Insulation resistance | MΩ | ≥500 |
| Compensated operating range | ° С | -10 … + 40 |
| Operating temperature range | ° С | -40 … + 80 |
| Sensor material | steel | |
| Protection class (according to EN60529 classification) | IP68 | |
| Cable length | m | 13 |
| Cable diameter | mm | 8 |
| Mass | kg | 22.5 |
| Package weight and dimensions | cm / kg | 25 x 33 x 23 / 24.5 |











Reviews