{"id":779,"date":"2020-09-03T11:14:22","date_gmt":"2020-09-03T08:14:22","guid":{"rendered":"http:\/\/agrospain.es\/?post_type=product&#038;p=779"},"modified":"2024-03-29T22:43:41","modified_gmt":"2024-03-29T19:43:41","slug":"bs","status":"publish","type":"product","link":"https:\/\/agrospain.es\/en\/shop\/bs\/","title":{"rendered":"Strain gauges BS"},"content":{"rendered":"<p><strong>Tensometric sensors BS 200-500-1000-2000 kg<\/strong><\/p>\n<p>Sensors &#8220;Cantilever beam&#8221; model BS are manufactured specifically for weighing and force measuring systems of industrial purpose. This model is characterized by linearity, temperature compensation, high reliability and stability of output signals. The degree of protection is IP68, the material is stainless steel, thanks to which the load cell is resistant to the influence of chemically aggressive environments and water.<\/p>\n<p>VS sensors, designed on the principle of a cantilever shear beam, are distinguished by their resistance to low profile and horizontal loads, which allows them to work in tank weighing systems, as well as in processes and automatic weighing systems of low or medium capacity. They are ideal for the chemical, food, and oil industries, and can be successfully used in the production of fertilizers and soda.<\/p>\n<div class=\"wrap-table\">\n<div class=\"wrap-table\">\n<table class=\"udata\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td class=\"udata\">Nominal load (Emax)<\/td>\n<td class=\"udata\">\u00a0kg<\/td>\n<td class=\"udata\" align=\"center\">200,500,1000,2000<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Accuracy class (OIML R 60)<\/td>\n<td class=\"udata\"><\/td>\n<td class=\"udata\" align=\"center\">\n<div class=\"wrap-table\">\n<div class=\"wrap-table\">\n<table border=\"0\" width=\"100%\">\n<tbody>\n<tr>\n<td align=\"center\" width=\"49%\">C1<\/td>\n<td align=\"center\" width=\"49%\">C3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Discreteness by class (\u00a0\u00a0<sup>n\u00a0\u00a0<\/sup><sub>LC<\/sub>\u00a0\u00a0)<\/td>\n<td class=\"udata\"><\/td>\n<td class=\"udata\" align=\"center\">\n<div class=\"wrap-table\">\n<div class=\"wrap-table\">\n<table border=\"0\" width=\"100%\">\n<tbody>\n<tr>\n<td align=\"center\" width=\"49%\">1000<\/td>\n<td align=\"center\" width=\"49%\">3000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Minimum weighing interval (V\u00a0\u00a0<sub>min<\/sub>\u00a0\u00a0)<\/td>\n<td class=\"udata\"><\/td>\n<td class=\"udata\" align=\"center\">\n<div class=\"wrap-table\">\n<div class=\"wrap-table\">\n<table border=\"0\" width=\"100%\">\n<tbody>\n<tr>\n<td align=\"center\" width=\"49%\">Emax \/ 5000<\/td>\n<td align=\"center\" width=\"49%\">Emax \/ 10000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">A common mistake<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">\n<div class=\"wrap-table\">\n<div class=\"wrap-table\">\n<table border=\"0\" width=\"100%\">\n<tbody>\n<tr>\n<td align=\"center\" width=\"49%\">\u00b1 0.05<\/td>\n<td align=\"center\" width=\"49%\">\u00b1 0.02<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Error of return to zero (DR)<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">0.00625<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Minimum load<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">0<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Maximum overload<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">150<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Horizontal overload is permissible<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">100<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Destructive overload<\/td>\n<td class=\"udata\">% Emax<\/td>\n<td class=\"udata\" align=\"center\">300<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Deformation (at Emax)<\/td>\n<td class=\"udata\">mm<\/td>\n<td class=\"udata\" align=\"center\">0.3<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Maximum excitation voltage (Umax)<\/td>\n<td class=\"udata\">IN<\/td>\n<td class=\"udata\" align=\"center\">15<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">RCP (Cn)<\/td>\n<td class=\"udata\">mV \/ V<\/td>\n<td class=\"udata\" align=\"center\">2 \u00b1 0.1<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Zero balance<\/td>\n<td class=\"udata\">% Cn<\/td>\n<td class=\"udata\" align=\"center\">\u00b1 1.0<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Input impedance<\/td>\n<td class=\"udata\">\u03a9<\/td>\n<td class=\"udata\" align=\"center\">385 \u00b1 20<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Output resistance<\/td>\n<td class=\"udata\">\u03a9<\/td>\n<td class=\"udata\" align=\"center\">350 \u00b1 3<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Insulation resistance<\/td>\n<td class=\"udata\">\u03a9<\/td>\n<td class=\"udata\" align=\"center\">&gt; 500<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Compensated operating range<\/td>\n<td class=\"udata\">\u00b0 \u0421<\/td>\n<td class=\"udata\" align=\"center\">-10 &#8230; + 40<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Operating temperature range<\/td>\n<td class=\"udata\">\u00b0 \u0421<\/td>\n<td class=\"udata\" align=\"center\">-40 &#8230; + 80<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Sensor material<\/td>\n<td class=\"udata\"><\/td>\n<td class=\"udata\" align=\"center\">Stainless Steel<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Protection class (according to EN60529 classification)<\/td>\n<td class=\"udata\"><\/td>\n<td class=\"udata\" align=\"center\">IP68<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Cable length<\/td>\n<td class=\"udata\">m<\/td>\n<td class=\"udata\" align=\"center\">5<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Cable diameter<\/td>\n<td class=\"udata\">mm<\/td>\n<td class=\"udata\" align=\"center\">5<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Mass<\/td>\n<td class=\"udata\">kg<\/td>\n<td class=\"udata\" align=\"center\">0.8<\/td>\n<\/tr>\n<tr>\n<td class=\"udata\">Package weight and dimensions<\/td>\n<td class=\"udata\">cm \/ kg<\/td>\n<td class=\"udata\" align=\"center\">10x27x6 \/ 1.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p><strong>\u00a0<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Tensometric sensors BS 200-500-1000-2000 kg Sensors &#8220;Cantilever beam&#8221; model BS are manufactured specifically for weighing and force measuring systems of industrial purpose. This model is characterized by linearity, temperature compensation, high reliability and stability of output signals. The degree of protection is IP68, the material is stainless steel, thanks to which the load cell is &hellip;<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/agrospain.es\/en\/shop\/bs\/\"> <span class=\"screen-reader-text\">Strain gauges BS<\/span> Read More &raquo;<\/a><\/p>\n","protected":false},"featured_media":1799,"comment_status":"open","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/product\/779"}],"collection":[{"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/comments?post=779"}],"version-history":[{"count":7,"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/product\/779\/revisions"}],"predecessor-version":[{"id":2263,"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/product\/779\/revisions\/2263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/media\/1799"}],"wp:attachment":[{"href":"https:\/\/agrospain.es\/en\/wp-json\/wp\/v2\/media?parent=779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}